Versatile, automated modular device empowers researchers to assemble a custom configuration perfectly suited to spatial learning and spatial memory studies in rats or mice.
The same modular device can be transformed into automated radial, Y, T and Delta mazes by simply rearranging the arms.
Surface texture is selected for best rodent comfort as well as optimal results with...
This software enables researchers to study behavior in a more reliable and consistent way and over longer time periods than if they were using direct observation or manual recording.
Highly advanced, comprehensive video-tracking system. The software couples an unrivalled depth of features with a simple, familiar design, to provide automated testing in virtually any behavioral...
The three-chamber test is the classic test to assess social behavior and memory in rodents. This may range from autism disease to dominance tests and social novelty. During the test one animal is freely moving while the other two are confined into circular grid bar cages.
The Ugo Basile system includes a high contrast or IR-transparent floor for the best quality video-tracking and grid...
Based on where a mouse with free movement spends its time in a central arena area with stimulus animals (familiar/unfamiliar/dominant/different gender) positioned in chambers on the outer edge.
For research into impairments in social skills that are central to mental disease and developing tools for their assessment in mouse models as well as smell related behavior (anosmia).
Patented non-invasive vital signs monitor. Measures heart rate, arterial oxygen saturation (SpO2), breath rate, and temperature (optional) of anesthetized and conscious small laboratory animals of various sizes.
Clinically validated and cited in a range of published studies including respiratory, neonatal, hypertension and brain injury.
Invasive arterial or venous blood pressure measurement during animal surgery. For urodynamic, intrauterine and intracranial studies. Also suitable for intensive care.
Connects to data acquisition systems such as our DataCapsule-Evo. High quality, robust, reusable and cost effective.
A multi-function, non-invasive blood pressure recorder for small to medium animals (mice to dogs) for use in a wide range of scientific studies.
Combines functionality of multiple systems including pressure generation-pressure monitoring system, pulse amplifier, thermal-array analog and digital recording unit and more. Single turn-key, stand-alone solution that can also be connected...
To perform Light/Dark Test with rats or mice for assessing anxiety. Useful in identifying and/or screening of anxiolytic and anxiogenic agents.
High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up, easy to clean.
The Delta-maze is a custom modification of the T-maze, a special design made possible by the extreme adaptability of our MultiMaze system 41500. The newest scientific research approaches, based on the available current technologies, often combine different methods in the same test in order to obtain more detailed and more interesting data. As an example, more and more often scientists need to...
The Radial Arm Maze has 8 equally spaced arms radiating from a central circular compartment.
It can be used for several sophisticated protocols to study spatial, working and reference learning and memory.
The animal can rely on egocentric or allocentric strategies. Working versus reference memory can be assessed by adopting intra or inter trial protocols. Easy to set up, easy to...
The Barnes Maze is a valid alternative to the water maze to study spatial learning and memory. The motivational drive is the rodent’s instinctive aversion for open spaces and natural preference for dark, “sheltered” spaces.
Reliable and durable. Optimized for use with video-tracking software. Available for mice or rats. Easy to set up, easy to clean.
Atlantis System allows platforms in a Morris Water Maze to rise gently to near the surface or go down automatically, using the manual controller or TTL signals. From one to four platform systems available.
Enables extinction protocols on rats or mice.
No need to stop the test to manually remove or reposition platforms.
A test for spatial learning and long-term memory in rodents. For research into neurocognitive disorders and treatments, aging, drug-abuse, neural systems, neurotransmitters and brain development.
High quality, strong and low weight. Embedded wheels for easy movement. Easy to drain and clean. Add optional Atlantis System to extend test capabilities. Different colors available.
Widely used to measure preference and spatial memory and learning tasks in laboratory animals. The simple T-shape design provides a single choice point with only two alternatives. Especially for CNS disorder studies.
High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent...
A simple Y-shape design provides rodents with a single choice point with only two alternatives. Widely used to measure preference and spatial memory and learning tasks in laboratory animals.
High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up,...
The Elevated Zero-Maze is an alternative model to the Elevated Plus Maze (EPM). Its circular design provides a smoother transition from closed to open space. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.
High quality maze with surface texture selected...
The elevated plus maze (EPM) is used to measure anxiety in rats and mice. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.
High quality maze with surface texture selected for best rodent comfort. Optimized for use with video tracking software (high...
The Open Field is used to assess exploratory behavior. Validated for use in the measurement of anxiety related behaviors. Also suited to the novel object recognition (NOR) test.
Decreased anxiety leads to increased exploratory behavior. Increased anxiety results in less locomotor motion and preference for the edges of the field.
The LUX Infrared (IR) illuminator allows for illumination from below of all the Ugo Basile IR mazes, which are made of an IR translucent plastic. This has the double advantage of: making experiments in the darkness easy and enhancing the contrast for better detection, no matter the animal color
The lux is available in 3 sizes, it guarantees a uniform illumination and incorporates IR...